📝 Introduction
Learn how to interpret PIP, Pplat, PEEP, and driving pressure on the ventilator. Understand lung compliance, VILI prevention, and ARDS ventilation strategies.
🗝️ Key Points
- 💨 Peak vs. Plateau Pressures: PIP reflects total airway resistance and compliance, while Pplat isolates alveolar compliance—elevations in both suggest decreased lung compliance (e.g., ARDS, pulmonary edema, pneumothorax).
- 🧱 PEEP Protects Alveoli: Maintains alveolar recruitment and prevents collapse; typical range 5–8 cmH₂O, but higher levels may benefit moderate–severe ARDS.
- ⚙️ Driving Pressure (ΔP = Pplat − PEEP): Lower ΔP reduces atelectrauma and improves outcomes; optimize by adjusting PEEP thoughtfully.
- 💥 Prevent VILI: Keep Pplat < 30 cmH₂O, use low tidal volumes (6 mL/kg IBW), and monitor for barotrauma, volutrauma, atelectrauma, and biotrauma.
- 📚 Evidence-Based Practice: ARDSNet and subsequent trials confirm that lung-protective ventilation—low Vt, limited pressures, and individualized PEEP—improves survival in ARDS.